Spezifikation

Produktbezug:
Produktnummer 4419925QBP
Handelsname / Bezeichnung Diethylaminsalicylat
CAS Nummer 4419-92-5
Andere Bezeichnungen / Synonyme•Diethylamine salicylate; •Diethylaminsalicylat; •Diethylammoniumsalicylat; •diethylammonium salicylate;
EG Nummer224-586-4
Zolltarifnummer / CN-Code29211950
Molekulargewicht [g/mol]211.3
Achtung --, --, --
Gesundheitsschädlich bei Verschlucken. Verursacht Hautreizungen. Verursacht schwere Augenreizung. Gesundheitsschädlich beim Einatmen.


Parameter Methode Spezifikation Einheit

Sensorische Prüfung
Aussehen SPA-1020-07 Klar
Aussehen SPA-1020-07 Weiß oder fast Kristalle, lichtempfindlich; sehr gut wasserlöslich, gut löslich in Ethanol (96%)
Farbe SPA-1020-07 ≤ BY5

Physikalische Parameter
Säuregehalt SPA-1020-07 4-Hydroxybenzoesäure ≤ 0,1 %
Säuregehalt SPA-1020-07 4-Hydroxyisophat ≤ 0,5 %
Säuregehalt SPA-1020-07 <0.2 ml NaOH 0.1N
Trocknungsverlust SPA-1020-07 ≤ 0,1 %
pH-Wert SPA-1020-07 5,0  –  7,0

Identifikation
Gehalt SPA-1020-07 99,0  –  101,0 %
Identifizierung SPA-1020-07 A (IR): IR Spektrum entspricht
Identifizierung SPA-1020-07 B: entspricht
Schmelzpunkt (Identität) SPA-1020-07 100  –  102 °C

Verunreinigungen
Schwermetalle (als Pb) SPA-1020-07 ≤ 10 ppm
Sulphat (SO4) SPA-1020-07 ≤ 250 ppm
Verunreinigung SPA-1020-07 ≤ 0,2 %
Verunreinigung SPA-1020-07 Irgendein anderer ≤ 0,5 %
Verunreinigung SPA-1020-07 Isopropyl alcohol ≤ 5000 ppm
Verunreinigung SPA-1020-07 Phenol ≤ 0,02 %

Restlösemittel
Heptane SPA-1020-07 ≤ 5000 ppm

Zusätzliche Angaben:

Lagerbedingungen: In gut verschlossenen Gebinden, vor Licht und Feuchtigkeit schützen

Verpackung: 25 kg Karton


Chemische Werke Hommel GmbH & Co.KG
Dieses Dokument wurde elektronisch erzeugt und ist ohne Unterschrift gültig.
Waltrop, 16. Jul. 2021
We only confirm that we took over the data from our supplier accordingly. Despite careful working, errors in the takeover are not totally excluded. Some or all parts off the document may be translated due to our best knowledge from the original to give a better understanding. If you have any questions about specific details, please call us directly. Unless otherwise marked, these data do not originate from us and have not been tested by us on the correctness. The above information corresponds to the present state of our knowledge and is intended as a general description of our products and their possible applications. We make no warranties, expressed or implied, as to the information's accuracy, adequacy, sufficiency or freedom from defect and assumes no liability in connection with any use of this information. Any user of this product is responsible for determining the suitability of our products for its particular application. The foregoing information does not absolve the buyer of its own tests. Observing existing laws and regulations, is the responsibility of the buyer of our product. Nothing included in this information waives any of our General Terms and Conditions of Sale, which control unless it agrees other in writing. Any existing intellectual/industrial property rights must be observed. Due to possible changes in our products and applicable national and international regulations and laws, the status of our products could change. Material Safety Data Sheets providing safety precautions, that should be observed when handling or storing our products, are available upon request and are provided in compliance with applicable law. The user should obtain and review the applicable Material Safety Data Sheet information before handling any of these products. For additional information, please contact us.